Hydraulic and
Mechanical Tools

HT Series: Hydraulic Testers


Specifications:

Product Type:
Hydraulic testers

Hydraulic Testers accurately measure oil flow, pressure and temperature on in-plant equipment, forklifts, machine tools and more.

50, 75 AND 200 GPM (200, 300 and 750 l/min) IN-LINE HYDRAULIC TESTERS

  • Accurately measure oil flow, pressure and temperature on in-plant equipment, forklifts, machine tools and more
  • Temperature and flow readings are in Metric and English, accurate to within ±2% of full scale
  • Dual pressure gauges for high and low pressure readings; low pressure gauge is automatically shut off and protected as pressure rises beyond its maximum reading
  • Automatic pressure compensating feature lets you increase flow without affecting pressure setting
  • Reverse flow through tester will not cause damage; replaceable safety disc ruptures if pressure exceeds upper limit
  • Solid state voltage regulator eliminates errors caused by voltage change during testing

50 GPM (200 l/min) IN-LINE HYDRAULIC TESTERS

  • Troubleshoots systems with capacities to 200 gpm (750 l/min) at pressures less than 5,000 psi (350 bar). Accurately measure oil flow to ±5%, pressure to within 2% and temperature readings within 1%
  • Pressure gauge is liquid filled to dampen system pulsation

For more precise low pressure readings, an optional dual pressure gauge kit is available.

Testing the Pump: Operator runs engine at a specific rpm and adjusts tester’s pressure compensating valve to simulate a work load. By comparing meter readings with manufacturer specs, proper operation of pump can be confirmed. If oil flow and pressure do not meet Specifications, the pump is faulty, Or, if test results and specifications agree, the operator will know that the problem is elsewhere in the system and that the other tests must be performed. Regardless of the component being tested, Hook-up and testing is accomplished in minutes.

Note: These hydraulic testers should always be used with the owner’s manual/manufacture’s specification for the system under the test.

Specifications

Order
Number
Maximum
Flow
(l/min)
Scale Flow
Ranges
(l/min.)
Maximum
Operating
Pressure
(bar)
Temperature
Scale
Range
(°C)
Port Sizes Weight
(kg.)
HT50A 200 0-200 345 -6 to 114 1 1/16-12UN Female “O” Ring
with Union Adapt. 3/4 ” Female NPTF
16.8
HT75 300 High
Low
50-300
10-60
345 40-120 3/4 ” NPT Swivel 8.6
HT200 750 High
Low
100-750
20-150
345 40-120 1 1/2 “* SAE Split Flange 13.6
* Not included, must be ordered separately.